The PDFM 5.1 Portable Doppler Flow Meter is a portable flow meter that clamps to the outside of a pipe to gain pipe flow measurement. The ultrasonic Doppler technology used by the PDFM 5.1 makes it perfect for use as a water flow meter, specifically for dirty or difficult liquids that contain bubbles or solids, like wastewater, slurries, sludge, chemicals, viscous liquids, and abrasives.

The PDFM 5.1 is ideal for evaluating system performance and can be installed, calibrated, and started up in minutes. Use this flow meter where a permanent flow meter is not required, or temporarily replace installed flow meters. Fast and easy to operate, the sensor mounts to the outside of a pipe in less than a minute, using the built-in keypad and calibration menu to set up the flowmeter for the application.   

With its internal battery, the PDFM 5.1 will operate all day and recharge overnight. For continuous use, it can be powered by a supplied 110-240 V AC wall plug adaptor or use Sleep Mode to only wake up the meter to take a measurement periodically, extending battery life. A 300,000-point data logger is built into the unit.

Display units can be selected by the user, and the PDFM 5.1 Portable Doppler Flow Meter will display and totalize flow in gallons, liters, cubic feet, or cubic meters. If you change from one measurement system to another, the PDFM 5.1 will automatically and instantly calculate and covert the total flow display and totalizer. Calibrate to the pipe size using the keypad to enter the inside diameter.

The 4-20mA output featured on the unit allows you to use the PDFM 5.1 Portable Doppler Flow Meter in critical applications. Ideal applications for this ultrasonic flow meter, with a non-contacting clamp-on ultrasonic sensor include influent and effluent pipe flow, industrial pipe flows, irrigation flows, food and beverage manufacturers, pharmaceutical processes, and many more!

Gain a full overview of our pipe flow measurement solutions by contacting a member of our team today.

Gain a full overview of our pipe flow measurement solutions by contacting one of our team today.

  • Clamp-on Ultrasonic Transducer
  • Handheld Meter with large backlit LCD Display and Totalizer
  • Internal Battery and/or AC Powered
  • Built-in 5-Key Calibrator
  • 300,000 point Data Logger
  • USB Output and Windows software
  • 4-20 mA Output
  • Rugged, watertight Carry Case
General Specifications
Spec name: Description:
Flow Rate Range ±0.046 m/s to 12.2 m/s (±0.125 ft/s to 40 ft/s) in most applications
Flow Rate Range Ultrasonic Sensor mounts on any pipe from 12.5 mm to 4.5 m (0.5 in to 180 in) ID
Display White, backlit matrix - displays flow rate, totalizer, operating mode, and calibration menu
Power Input Built-in NiMH battery for up to 18 hours continuous operation External charger with 100-240 V AC 50/60 Hz input
Outputs 4-20 mA (500 ohms) when AC powered USB for Data Log transfer by direct PC connection
Data Logger Programmable 300,000 data point capacity, time and date stamped or formatted flow reports including total, average, minimum, maximum, and times of occurrence
PC Software 'Greyline Logger' for Windows Vista or higher. Retrieves, displays, and saves data log files
Operating Temperature (Electronics) -23 °C to 60 °C (-10 °F to 140 °F)
Electronics Enclosure Portable, ABS enclosure
Carry Case Rated IP67 with protective molded foam insert
Accuracy ±2% of reading or 0.03 m/s (0.1 ft/s). Requires solids or bubbles minimum size of 100 microns, minimum concentration 75 ppm. Repeatability: ±0.1%, Linearity ±0.5%
Calibration Built-in 5-key programming with a user-friendly calibration menu. Password protected.
Language Selection English, French, Spanish
Sensitivity Adjustable cut-off, Damping: adjustable

Sensor Specifications
Spec name: Description:
Standard Model PSE4 Clamp-on, single-head ultrasonic for pipes from 12.5 mm to 4.5 m (0.5 in to 180 in) ID with 3.4 m (12 ft) shielded dual-coaxial cable
Sensor Mounting Kit Stainless steel pipe clamp and 150 g (5.3 oz) silicone coupling compound
Operating Temperature -40 °C to 150 °C (-40 °F to 300 °F)
Options
Options: Description:
Sensor Cable 15 m (50 ft) sensor cable extension, shielded, with connectors
Sensor Mounting Extra silicone coupling compound. Additional stainless steel pipe clamps
Sand slurry measurement with PDFM 5.1 pdf Download
Installation & Instruction Manual pdf Download
Engineering Specifications pdf Download
Pulsar Logger v3.0.0 Software (Formerly Greyline Logger) pdf Download
Software Brochure pdf Download
Doppler and Transit Time for non-invasive measurement of flow in full pipes. pdf Download
The limestone slurry is abrasive so in-line flowmeters are not practical. Non-contacting Doppler flowmeters can be used both on the fly ash slurry supply lines and on "used" or recirculated slurry. pdf Download
Datasheet pdf Download
Datasheet pdf Download
Case Study | Portable flow meters solve flow rate discrepancies between pump station effluent and lagoon influent flow meters. pdf Download

Charger

  • CE
  • UL

Transmitter

  • Not certified for use in hazardous rated locations