dB3 with Double Sun Shields

Specialist Ultrasonic Flow Transducer

dB3 sensor with Double Sun Shields
Découvrez les points forts
overview Aperçu
features Caractéristiques
specifications Caractéristiques
downloads Téléchargements
approvals Approbations
Galerie

When combined with the Ultra 4 Controller, the dB3 with double sun shields has achieved MCERTS Class 1 Certification with 0.136% combined accuracy. This means that the pair have been independently tested and performed well under rigorous conditions. Utilities across the globe can now be confident that their flow measurement is of the highest possible accuracy by using MCERTS certified equipment.

The dB3 with double sun shields is specifically designed for open channel flow applications. One of the critical conditions of ultrasonic measurement is the measurement distance, therefore, its short measurement range of 3 m (9ft) and maximized accuracy at zero blanking meet this requirement. The double sun shields of the dB3 help to protect the transducer from solar radiation and combats ambient temperature changes that could ultimately affect the flow and level readings.

To achieve the MCERTS Class 1 Certification, the dB3 with double sun shields must be combined with the Ultra 4 controller from Pulsar Measurement. If you’d like to discuss your application requirements, please don’t hesitate to contact one of our friendly team who will be happy to help.

  • MCERTS Class 1 Certification when combined with the Ultra 4
  • Short measurement range, increases accuracy
  • Protection from solar radiation
  • Zero blanking distance
General Specifications
Spec:Description:
Sensor Body Dimensions:180 mm D (sunshield) x 115 mm H (7.08 in x 4.5 in)
Weight:

Nominal 1.1 kg (2.4 lb)

Max. and Min Temperature (Electronics):

Standard: -40 °C to +90 °C (-40 °F to +194 °F) ATEX: -40 °C to +75 °C (-40 °F to +167 °F)

Measurement Range:

125 mm to 3 m (4.9 in to 9.8 ft)
Accuracy:

0.25% or 6 mm (0.2 in) whichever is greater

Resolution:

0.01% or 2 mm (0.08 in) whichever is greater

Sensor Body Material:

Valox 357 U and syntactic foam face

Maximum Separation:

500 m (1,640 ft)

Mounting Connection:

BSP or 1” NPT

ENVIRONMENTAL

Enclosure Protection:

IP68 / NEMA 6P

APPROVALS

CE Approval:

2014/30/EU - EMC & 2014/34/EU ATEX Directives. Standards applied: EN 60079-0:2012+A11:2013/ EN 60079-11:2012 / EN 60079-18:2009 / EN 60079-26:2007 / EN 61326-1:2013

ATEX Approval:

Standard ATEX EEx m II T6 or optional EEx ia IIC T6. FM/FMC approval.

MCERTs Certification:

Class 1 (0.136%) when used with Ultra 4

PERFORMANCE

Frequency:

125kHz

Beam Angle:

<10°

Fiche de données pdf Télécharger
MCERTS Certification pdf Télécharger
Case Study | Techno Bangla Engineering Ltd provides a non-contacting flow measurement solution to the pharmaceutical industry. pdf Télécharger
Pulsar Measurement Product Warranty pdf Télécharger
  • CE Approval: 2014/30/EU - EMC & 2014/34/EU ATEX Directives.
  • CE Standards Applied: EN 60079-0:2012+A11:2013
  • EN 60079-11:2012
  • EN 60079-18:2009
  • EN 60079-26:2007
  • EN 61326-1:2013
  • ATEX: Standard ATEX EEx m II T6 or optional EEx ia IIC T6.
  • FM/FMC Approval
  • MCERTS Class 1 Certification (when combined with the Ultra 4)

Demander un devis

Formulaire rapide

Demander un devis
productconfigurator-section

Configurateur de produit

Le configurateur de produits Pulsar Measurement vous permet de sélectionner les applications qui vous sont spécifiques et de découvrir les solutions les plus adaptées à vos besoins.

Questions?

Besoin d'aide ?

Si vous avez besoin d'aide ou d'assistance, n'hésitez pas à nous contacter dès aujourd'hui.